Automatic Tank Filling System, Ready Kit, 100% Tested
Abstract
Automatic Tank Filling System circuit is presented here is based on the readily available moisture sensor, comparator IC LM393 and relay. The moisture sensor is used as moisture detector while IC LM393 used as comparator. In the absence of water, no moisture sense in the soil. As a result moisture sensor start conducting and turn ON the water pump. However, when there is a moisture present in the tank the moisture sensor detect moisture and water pump stays off.
Buy Online “Automatic tank filling system” Ready Kit, 100% Tested from below and get fastest delivery in India
https://smartxprokits.in/product/automatic-tank-filling-system-kit-assembled-100-tested/
Complete working video can be seen from
Follow us on Instagram
Application of the circuit:
Most of the moisture sensor based circuits available in market use one or another kind of moisture detector probe which increases the cost and also require complicated circuitry around it. But this moisture sensor based circuit uses readily available moisture detector probe as moisture detector. The functioning of this Automatic Tank Filling System circuit is to detect moisture in tank and automatically activate the water pump in absence of moisture. Water pump is ON continuously indicating the absence of moisture till it detects moisture on moisture sensor.
Why this particular circuit:
Moisture detector probe used here as a moisture detector. The variation in moisture wanted can be easily done by introducing water. The circuit operates normally over a DC voltage of 5V which can be obtained by DC supply cable.
Explained working of circuit:
The basic idea behind the circuit operation is to turn ON water pump in absence of moisture. The moisture detector probe is needed for this purpose. Moisture detector probe is a device that converts tank moisture to electric energy. Here, Automatic Tank Filling System circuit works as moisture detector while moisture detector probe working as moisture sensor that turns ON water pump. IC LM393 is used as comparator. Moisture detector probe output is connected as input to comparator. Pin no. 4 of LM393 is pulled towards ground. Relay is used as a switch. When relay is activated, normally closed contact becomes open and normally open contact becomes closed. In normal condition, there is moisture in the tank and water pump stays off. Now consider second scenario when there is no moisture in the tank, the water pump turns ON.
How to build:
First of all read the given manual thoroughly and study the circuit given in the figure. Also have look at PCB and components supplied along with the kit. Each component has to be soldered in its position on PCB.
Identification of resistors is done by color coding. The color band on each resistor corresponds to its exact value.
There are different methods in which values are defined on capacitors. But usually values are specified numerically on them.
Can you make out the whole working of circuit and are you able to identify each component separately as to where each of them has to be placed?
If yes only then proceed further to actually mounting and soldering the parts.
Not ICs but their sockets are to be soldered on PCB. This is to make mounting and dismounting of ICs easy while troubleshooting.
Start from left most corner of PCB and solder the components one by one on their correct position on PCB.
Before soldering any component see that you have placed it at its right position and with correct polarity. Give due attention to diodes and electrolytic capacitors as they are polarity dependent.
Do the soldering of other components in the same way while keeping in mind that components with long and sensitive leads like capacitors and transistors are soldered last.
Testing the kit:
After assembling and soldering of components on PCB, connect external DC power source of 5V.
For testing purpose manually water is induced. Pump turns on in absence of water.
Now set the desired intensity at which you want detection of light. This can be done by changing the resistive value of R2 variable resistor.
Install the unit in tank.
ICs used here:
The only IC used here is LM393
It is dual differential comparator IC.
This 8 pin IC is popular and commonly used IC
Part List
Semiconductors
U1 – LM393
https://smartxprokits.in/product/lm393/
Base – 8 pin
https://smartxprokits.in/product/8-pin-dip-ic-socket-base-adaptor/
Resistors(all ¼ watt +/-5% carbon unless stated otherwise)
R2 – 10k Ohm(variable)
https://smartxprokits.in/product/10k-multiturn-potentiometer/
R3 – 1k Ohm
https://smartxprokits.in/product/1k-resistor-1-4-watt/
R4 – 1k Ohm
https://smartxprokits.in/product/1k-resistor-1-4-watt/
R5 – 10k Ohm
https://smartxprokits.in/product/10k-resistor-1-4-watt/
R6 – 10k Ohm
https://smartxprokits.in/product/10k-resistor-1-4-watt/
Capacitor C1 – 1uF
Miscellaneous
D4: – moisture sensor
D1: – Red LED
https://smartxprokits.in/product/3mm-red-led/
D2: – Green LED
https://smartxprokits.in/product/3mm-green-led/
5 V USB Cable
https://smartxprokits.in/product/micro-usb-cable/
PCB
Pump
https://smartxprokits.in/product/5v-dc-mini-submersible-water-pump/
Relay
https://smartxprokits.in/product/5v-10a-pcb-mount-relay-spdt/